Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(6): 064501, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243499

RESUMO

The Primordial Inflation Polarization Explorer (PIPER) is a stratospheric balloon payload to measure the polarization of the cosmic microwave background. Twin telescopes mounted within an open-aperture bucket dewar couple the sky to bolometric detector arrays. We reduce detector loading and photon noise by cooling the entire optical chain to 1.7 K or colder. A set of fountain-effect pumps sprays superfluid liquid helium onto each optical surface, producing helium flows of 50-100 cm3 s-1 at heights up to 200 cm above the liquid level. We describe the fountain-effect pumps and the cryogenic performance of the PIPER payload during two flights in 2017 and 2019.

2.
Rev Sci Instrum ; 91(12): 124501, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33380000

RESUMO

The balloon-borne cryogenic telescope testbed is a stratospheric balloon payload intended to develop technology for a future cryogenic suborbital observatory. A series of flights are intended to establish ultra-light dewar performance and open-aperture observing techniques for large (3 m-5 m diameter) cryogenic telescopes at infrared wavelengths. An initial flight in 2019 demonstrated bulk transfer of liquid nitrogen and liquid helium at stratospheric altitudes. An 827 kg payload carried 14 l of liquid nitrogen (LN2) and 268 l of liquid helium (LHe) in pressurized storage dewars to an altitude of 39.7 km. Once at float altitude, liquid nitrogen transfer cooled a separate, unpressurized bucket dewar to a temperature of 65 K, followed by the transfer of 32 l of liquid helium from the storage dewar into the bucket dewar. Calorimetric tests measured the total heat leak to the LHe bath within the bucket dewar. A subsequent flight will replace the receiving bucket dewar with an ultra-light dewar of similar size to compare the performance of an ultra-light design dewar to that of conventional superinsulated dewars.

3.
Sensors (Basel) ; 20(3)2020 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-32033139

RESUMO

The permittivity of blood glucose is not a strong function of its concentration in microwave or millimeter-wave frequencies. Measuring glucose concentrations remains a challenge, particularly in the presence of interference caused by the ambient leaky waves. In this paper, however, we demonstrate that a near-linear correlation between the glucose concentration and the blood permittivity was noticeably observed at a whispering gallery mode resonance. METHOD: the proposed sensor was a vacuum suction aspirator partially wounded with a turn of the Goubau line. This arrangement enabled a fixed cylindrical volume of a skin tissue bump or glucose/water solution to be formed and used as a whispering gallery resonator for in-vivo and ex-vivo measurements. RESULTS: in the in-vivo study, a near-linear correlation between the glucose levels and the S21 parameters was noticeably observed at the fundamental whispering gallery resonance (i.e., at 2.18 GHz). In the ex-vivo study, a similar correlation was observed between the concentration of a glucose/water solution and the S21 parameters 56.6 GHz. CONCLUSION: the results of both investigations were consistent not only with the invasive measurements using the Accu-checkTM, but also with the conclusion drawn by some other research groups who have successfully measured blood glucose concentrations at millimeter-wave frequencies.


Assuntos
Técnicas Biossensoriais , Automonitorização da Glicemia/instrumentação , Glicemia/análise , Pele/patologia , Algoritmos , Automonitorização da Glicemia/métodos , Radiação Eletromagnética , Voluntários Saudáveis , Humanos , Micro-Ondas , Reconhecimento Automatizado de Padrão , Imagens de Fantasmas , Reprodutibilidade dos Testes , Água/análise
4.
Rev Sci Instrum ; 90(9): 095104, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31575233

RESUMO

The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne telescope mission to search for inflationary gravitational waves from the early universe. PIPER employs two 32 × 40 arrays of superconducting transition-edge sensors, which operate at 100 mK. An open bucket Dewar of liquid helium maintains the receiver and telescope optics at 1.7 K. We describe the thermal design of the receiver and sub-Kelvin cooling with a continuous adiabatic demagnetization refrigerator (CADR). The CADR operates between 70 and 130 mK and provides ≈10 µW cooling power at 100 mK, nearly five times the loading of the two detector assemblies. We describe electronics and software to robustly control the CADR, overall CADR performance in flightlike integrated receiver testing, and practical considerations for implementation in the balloon float environment.

5.
Restor Neurol Neurosci ; 34(1): 79-95, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26599475

RESUMO

PURPOSE: Providing mobility solutions for individuals with tetraplegia remains challenging. Existing control devices have shortcomings such as varying or poor signal quality or interference with communication. To overcome these limitations, we present a novel myoelectric auricular control system (ACS) based on bilateral activation of the posterior auricular muscles (PAMs). METHODS: Ten able-bodied subjects and two individuals with tetraplegia practiced PAM activation over 4 days using visual feedback and software-based training for 1 h/day. Initially, half of these subjects were not able to voluntarily activate their PAMs. This ability was tested with regard to 8 parameters such as contraction rate, lateralized activation, wheelchair speed and path length in a virtual obstacle course. In session 5, all subjects steered an electric wheelchair with the ACS. RESULTS: Performance of all subjects in controlling their PAMs improved steadily over the training period. By day 5, all subjects successfully generated basic steering commands using the ACS in a powered wheelchair, and subjects with tetraplegia completed a complex real-world obstacle course. This study demonstrates that the ability to activate PAM on both sides together or unilaterally can be learned and used intuitively to steer a wheelchair. CONCLUSIONS: With the ACS we can exploit the untapped potential of the PAMs by assigning them a new, complex function. The inherent advantages of the ACS, such as not interfering with oral communication, robustness, stability over time and proportional and continuous signal generation, meet the specific needs of wheelchair users and render it a realistic alternative to currently available assistive technologies.


Assuntos
Orelha/fisiopatologia , Eletromiografia/métodos , Músculo Esquelético/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Interface Usuário-Computador , Cadeiras de Rodas , Retroalimentação Sensorial , Feminino , Lateralidade Funcional , Humanos , Masculino , Satisfação do Paciente , Prática Psicológica , Quadriplegia/fisiopatologia , Quadriplegia/reabilitação , Processamento de Sinais Assistido por Computador , Traumatismos da Medula Espinal/fisiopatologia , Adulto Jovem
6.
Rev Sci Instrum ; 85(6): 064501, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24985830

RESUMO

We describe the design, construction, and initial validation of the variable-delay polarization modulator (VPM) designed for the PIPER cosmic microwave background polarimeter. The VPM modulates between linear and circular polarization by introducing a variable phase delay between orthogonal linear polarizations. Each VPM has a diameter of 39 cm and is engineered to operate in a cryogenic environment (1.5 K). We describe the mechanical design and performance of the kinematic double-blade flexure and drive mechanism along with the construction of the high precision wire grid polarizers.

7.
Phys Rev Lett ; 75(7): 1264-1267, 1995 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-10060249
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...